sketch of an in-line arrester

Selecting The Right Product

In-Line Deflagration & Detonation Flame Arrestors

Elmac Technologies® can supply different types of in-line deflagration and unstable detonation arrestors, suitable for a wide variety of industries and applications. CE-IB unstable detonation arrestors are suitable for gas groups up to IIB3. DFB and SGE-IB deflagration arrestors are also suitable for use up to gas group IIB3. MB-IB microbore deflagration arrestors are specifically designed for use in process and instrumentation lines. CE-IB, DFB, and SGE-IB arrestors all have replaceable elements.

The tables below show which products are suitable for which gas groups, as well as the connection sizes available. Follow the product links for detailed product information for each series.

ce-ib detonation arrester dfb deflagration arrester dfc deflagration arrester mb-ib microbore flame arrester sge-ib in-line deflagration arrester
CE-IB Unstable
Detonation Arrestors
DFB Deflagration
Flame Arrestors
DFC Deflagration
Flame Arrestors
MB-IB Microbore
Arrestors
SGE-IB Deflagration
Flame Arrestors



sge-ib deflagration arrester

In-Line Flame and Detonation Arrestors

In-line deflagration arrestors are designed to prevent propagation of flames in gas or vapour mixtures. By locating the arrestor in close proximity to the potential source of ignition, any flame or explosion is confined to the immediate area.

Unstable detonation arrestors* are designed to prevent propagation of detonations in gas or vapour mixtures. Detonation arrestors are specifically designed for pipelines with a significant distance between the ignition source and the arrestor, or for use where the pipe is rough, bent, obstructed or has section changes.

* For more information regarding Elmac's policy on stable and unstable detonation arrestors, please see the Guidance Notes in the Elmac Data Centre.

Table 1a. In-Line Arrestor Gas Group & Service Suitability
Gas GroupIIIAIIB3IIBIICDeflagrationDetonation
CE-IB   --  
DFB   -- -
DFC---   -
MB-IB   -- -
SGE-IB   -- -

Table 1b. In-Line Arrestor Size Ranges
Nominal Bore (mm)1520253240506580100125150200250300350400
CE-IB            ----
DFB-- -  -  - -----
DFC-- -  -  - -----
MB-IB  --------------
SGE-IB                



request a quotation button

Still not sure?

Our Customer Services team is just a phone call away.

If you are still not sure which flame arrestor product you need, or have a query about specific options or requirements, or would like some more advice, please do not hesitate to get in touch with our Customer Services team. Details are shown on the left of this page.

© 2012 Elmac Technologies
Elmac Technologies specialises in the manufacture of Flame Arresters and supply of Pressure Relief Equipment.
Privacy Policy  Terms & Conditions